EasyManua.ls Logo

Omron RX Series - Page 201

Omron RX Series
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 5
5 Basic Settings
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
5-1 Parameter Display and Parameter Initialization
5
5-1-1 Display Selection
Displays only the parameters set in U001 to U012.
In addition to U001 to U012, the parameter d001, F001, and b037 are displayed.
Displays only the changed parameters from the factory default settings.
However, the parameters for analog input adjustment (C081 to C083, C121 to C123) and Thermistor
Adjustment (C085) are not displayed.
All monitor display parameters (d***) and F001 will be always displayed.
Displays only the basic parameters.
When this setting is enabled, the following parameters are displayed.
User Setting (b037 = 02)
Data Comparison Display (b037 = 03)
Basic Display (b037 = 04)
No.
Parameter
No.
Function name No.
Parameter
No.
Function name
1 d001 Output Frequency Monitor 18 A044 1st Control Method
2 d002 Output Current Monitor 19 A045 Output Voltage Gain
3 d003 RUN Direction Monitor 20 A085 Operation Mode Selection
4 d004 PID Feedback Value Monitor 21 b001
Power Interruption/Undervoltage
Restart Selection
5F001
Output Frequency
Setting/Monitor
22 b002
Allowable Power Interruption
Time
6 F002 1st Acceleration Time 1 23 b008
Overvoltage/Overcurrent Restart
Selection
7 F003 1st Deceleration Time 1 24 b011
Overvoltage/Overcurrent Restart
Standby Time
8 F004 RUN Direction Selection 25 b037 Display Selection
9 A001 Frequency Reference Selection 26 b083 Carrier Frequency
10 A002 RUN Command Selection 27 b084 Initialization Selection
11 A003 1st Base Frequency 28 b130
Overvoltage Suppression
Function Selection During
Deceleration
12 A004 1st Maximum Frequency 29 b131
Overvoltage Suppression Level
During Deceleration
13 A005 FV/FI Selection 30 b180 Initialization Execution
14 A020
1st Multi-step Speed Reference 0
31 C021
Multi-function Output P1
Selection
15 A021 Multi-step Speed Reference 1 32 C022
Multi-function Output P2
Selection
16 A022 Multi-step Speed Reference 2 33 C036
Multi-function Relay Output (MA,
MB) Operation Selection
17 A023 Multi-step Speed Reference 3
Related functions U001 to U012

Table of Contents

Related product manuals