5 Basic Settings
5 - 14
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
b022
Overload
Limit Level
0.20 x Heavy-load rated
current to 2.00 x Heavy-load
rated current [A] (0.20 x
Heavy-load rated current to
1.80 x Heavy-load rated
current [A]
0.20 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.20 x
Light-load rated current to
1.50 x Light-load rated
current [A])
1.50 x
Heavy-load
rated
current [A]
1.20 x
Light-load
rated
current [A]
Enabled
Conversion
*1
b025
Overload
Limit Level 2
b028
Frequency
Pull-in
Restart Level
0.20 x Heavy-load rated
current to 2.00 x Heavy-load
rated current [A] (0.20 x
Heavy-load rated current to
1.80 x Heavy-load rated
current [A])
0.20 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.20 x
Light-load rated current to
1.50 x Light-load rated
current [A])
Heavy-load
rated
current [A]
Light-load
rated
current [A]
Enabled
Conversion
*1
b041
Torque Limit 1
(Four-quadrant
Mode Forward
Power
Running)
Percentage of heavy-load
rated current
0. to 200.[%] (0. to 180.[%])
no: Function disabled
Percentage of light-load
rated current
0. to 150.[%] (0. to 150.[%])
no: Function disabled
150.[%] 120.[%] Enabled Disabled
b042
Torque Limit 2
(Four-quadrant
Mode Reverse
Regeneration)
b043
Torque Limit 3
(Four-quadrant
Mode Reverse
Power
Running)
b044
Torque Limit 4
(Four-quadrant
Mode Forward
Regeneration)
b083
Carrier
Frequency
0.5 to 15.0 [kHz] (0.5 to 10.0
[kHz])
0.5 to 12.0 [kHz] (0.5 to 8.0
[kHz])
5.0 [kHz]
(3.0 [kHz])
3.0 [kHz]
(3.0 [kHz])
Enabled Disabled
C030
Digital
Current
Monitor
Reference
Value
0.20 x Heavy-load rated
current to 2.00 x Heavy-load
rated current [A]
0.20 x Light-load rated
current to 1.50 x Light-load
rated current [A]
Heavy-load
rated
current [A]
Light-load
rated
current [A]
Enabled
Conversion
*1
C039
Low Current
Detection
Level
0.00 x Heavy-load rated
current to 2.00 x Heavy-load
rated current [A] (0.00 x
Heavy-load rated current to
1.80 x Heavy-load rated
current [A])
0.00 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.00 x
Light-load rated current to
1.50 x Light-load rated
current [A])
Heavy-load
rated
current [A]
Light-load
rated
current [A]
Enabled
Conversion
*1
C041
Overload
Warning
Level
0.00 x Heavy-load rated
current to 2.00 x Heavy-load
rated current [A] (0.00 x
Heavy-load rated current to
1.80 x Heavy-load rated
current [A])
0.00: Function disabled
0.00 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.00 x
Light-load rated current to
1.50 x Light-load rated
current [A])
0.00: Function disabled
Heavy-load
rated
current [A]
Light-load
rated
current [A]
Enabled
Conversion
*1
No.
Parameter
name
Setting range Default data
Initialization at
mode switching
Heavy load (CT) Light load (VT)
Heavy load
(CT)
Light load
(VT)
Heavy
to Light
Light to
Heavy

Table of Contents