EasyManua.ls Logo

Omron RX Series - Page 361

Omron RX Series
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 35
7 Detailed Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
7-3 Basic Functions (Group A)
7
This setting is suitable for cart, conveyor, overhead traveling crane, and other applications where a
constant torque is required, independent of the motor rotation speed.
The output voltage is generated in proportion to the output frequency to realize the output of a constant
torque.
However, the output voltage is proportional from 0 Hz to the base frequency, it is constant independent
of the frequency, from the base frequency to the maximum frequency.
For the base frequency, set the rated frequency of the motor. For the maximum frequency, set the
highest frequency required for your application, within the maximum frequency of the motor.
This setting is suitable for fan, pump, and other applications that do not require large torque at low
speeds.
It provides high efficiency, reduced noise, and vibration, because the output voltage is reduced in the
low speed range.
In only the low speed range at 10% of the base frequency or less, the setting provides constant torque
characteristics (VC) to secure a sufficient starting torque.
Range (a):
Constant torque characteristics are provided from 0 Hz to 10% of the base frequency.
(Example)If the base frequency is 60 Hz, the setting provides constant torque characteristics from 0 to
6 Hz.
Range (b):
Reduced torque characteristics are provided from 10% to 100% of the base frequency.
The inverter outputs voltage based on a curve of the 1.7th power of the frequency.
Range (c):
Constant voltage characteristics are provided from the base frequency to the maximum frequency.
Constant Torque Characteristics (VC)
Reduced Torque Characteristics (VP 1.7th Power (VC at Low Speed))
0
Output
voltage [%]
Base frequency
Output frequency [Hz]
Max. frequency
0
Output
voltage [%]
Base
frequency
Output frequency [Hz]
Max.
frequency
VC
VP(f )
10% of base
frequency
1.7
(a)
(b)
(c)

Table of Contents