8 Communications Functions
8 - 42
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
124A hex 1249 hex
DC Injection Braking
Edge/Level Selection
A056 R/W
00: Edge operation
01: Level operation
124B hex 124A hex
Startup DC Injection Braking
Power
A057 R/W
0 to 100 (0.4 to 55 kW)
0 to 80 (75 to 132 kW)
(In the light mode)
0 to 70 (0.4 to 55 kW)
0 to 50 (75 to 132 kW)
1 [%]
124C hex 124B hex
Startup DC Injection Braking
Time
A058 R/W 0 to 600 0.1 [s]
124D hex 124C hex
DC Injection Braking Carrier
Frequency
A059 R/W
5 to 150 (0.4 to 55 kW)
5 to 100 (75 to 132 kW)
(In the light mode)
5 to 120 (0.4 to 55 kW)
5 to 80 (95 to 132 kW)
0.01 [Hz]
124E hex Not used
124F hex 124E hex
1st Frequency Upper Limit
A061
(HIGH)
R/W
0
Frequency Lower Limit to Max.
Frequency
0.01 [Hz]
1250 hex 124F hex
A061
(LOW)
R/W
1251 hex 1250 hex
1st Frequency Lower Limit
A062
(HIGH)
R/W
0
Starting Frequency to
Frequency Upper Limit
0.01 [Hz]
1252 hex 1251 hex
A062
(LOW)
R/W
1253 hex 1252 hex
Jump Frequency 1
A063
(HIGH)
R/W
0 to 40000 0.01 [Hz]
1254 hex 1253 hex
A063
(LOW)
R/W
1255 hex 1254 hex Jump Frequency Width 1 A064 R/W 0 to 1000 0.01 [Hz]
1256 hex 1255 hex
Jump Frequency 2
A065
(HIGH)
R/W
0 to 40000 0.01 [Hz]
1257 hex 1256 hex
A065
(LOW)
R/W
1258 hex 1257 hex Jump Frequency Width 2 A066 R/W 0 to 1000 0.01 [Hz]
1259 hex 1258 hex
Jump Frequency 3
A067
(HIGH)
R/W
0 to 40000 0.01 [Hz]
125A hex 1259 hex
A067
(LOW)
R/W
125B hex 125A hex Jump Frequency Width 3 A068 R/W 0 to 1000 0.01 [Hz]
125C hex 125B hex
Acceleration Stop Frequency
A069
(HIGH)
R/W
0 to 40000 0.01 [Hz]
125D hex 125C hex
A069
(LOW)
R/W
125E hex 125D hex Acceleration Stop Time A070 R/W 0 to 600 0.1 [s]
125F hex 125E hex PID Selection A071 R/W
00: Disabled
01: Enabled
02: Re
verse output enabled
1260
hex 125F hex PID P Gain A072 R/W 2 to 50 0.1
1261 hex 1260 hex PID I Gain A073 R/W 0 to 36000 0.1 [s]
1262 hex 1261 hex PID D Gain A074 R/W 0 to 10000 0.01 [s]
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution

Table of Contents