8 Communications Functions
8 - 70
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
* The 1st Motor Capacity (H003) takes the following code data.
16AC hex 16AB hex
Option I/F Flexible Format
Input Register 1
P170 R/W 0000 to FFFF hex 1
16AD hex 16AC hex
Option I/F Flexible Format
Input Register 2
P171 R/W 0000 to FFFF hex 1
16AE hex 16AD hex
Option I/F Flexible Format
Input Register 3
P172 R/W 0000 to FFFF hex 1
16AF hex 16AE hex
Option I/F Flexible Format
Input Register 4
P173 R/W 0000 to FFFF hex 1
16B0 hex 16BF hex
Option I/F Flexible Format
Input Register 5
P174 R/W 0000 to FFFF hex 1
16B1 hex 16B0 hex
Option I/F Flexible Format
Input Register 6
P175 R/W 0000 to FFFF hex 1
16B2 hex 16B1 hex
Option I/F Flexible Format
Input Register 7
P176 R/W 0000 to FFFF hex 1
16B3 hex 16B2 hex
Option I/F Flexible Format
Input Register 8
P177 R/W 0000 to FFFF hex 1
16B4 hex 16B3 hex
Option I/F Flexible Format
Input Register 9
P178 R/W 0000 to FFFF hex 1
16B5 hex 16B4 hex
Option I/F Flexible Format
Input Register 10
P179 R/W 0000 to FFFF hex 1
16B6 hex 16B5 hex Not used P180
Use default data.
* Do not set.
16B7 hex 16B6 hex Not used P181
Use default data.
* Do not set.
16B8 hex 16B7 hex Not used P182
Use default data.
* Do not set.
16B9 hex 16B8 hex Not used
16BA hex 16B9 hex Not used
16BB hex 16BA hex Not used P185
Use default data.
* Do not set.
16BC hex 16BB hex Not used P186
Use default data.
* Do not set.
16BD to
16BF hex
16BC to
16BE hex
Not used
16C0 hex 16BF hex CompoNet Node Address P190 R/W 0 to 63 1
16C1 hex 16C0 hex Not used
16C2 hex 16C1 hex DeviceNet MAC ID P192 R/W 0 to 63 1
16C3 to
2102 hex
16C2 to
2101 hex
Not used
Code data 00 01 02 03 04 05 06 07 08 09 10
Motor capacity [kW] 0.2 0.4 0.75 1.5 2.2 3.7
Code data 11 12 13 14 15 16 17 18 19 20 21
Motor capacity [kW] 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Code data 22 23 24 25 26
Motor capacity [kW] 90 110 132 150 160
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution