8 - 73
8 Communications Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
8-5 Modbus Communication Register Number List
8
8-5-5 2nd Control Register Number List
230D hex 230C hex
2nd Electronic Thermal
Characteristics Selection
b213 R/W
00: Reduced torque
characteristics
01: Constant torque
characteristics
02: Free setting
230E to
2501 hex
Not used
2502 hex 2501 hex
2nd Motor Parameter
selection
H202 R/W
00: Standard motor parameter
01: Auto-tuning
02: Auto-tuning (Online
auto-tuning enabled)
2503 hex 2502 hex 2nd Motor Capacity H203 R/W Refer to page 8-74.
2504 hex 2503 hex 2nd Motor Pole Number H204 R/W
0: 2P
1: 4P
2: 6P
3: 8P
4: 10P
2505 hex 2504 hex
2nd Speed Response
H205
(HIGH)
R/W
1 to 80000 0.001
2506 hex 2505 hex
H205
(LOW)
R/W
2507 hex 2506 hex 2nd Stabilization Parameter H206 R/W 0 to 255 1
2508 to
2514 hex
Not used
2515 hex 2514 hex
2nd Motor Parameter R1
H220
(HIGH)
R/W
1 to 65535 0.001 [Ω]
2516 hex 2515 hex
H220
(LOW)
R/W
2517 hex 2516 hex
2nd Motor Parameter R2
H221
(HIGH)
R/W
1 to 65535 0.001 [Ω]
2518 hex 2517 hex
H221
(LOW)
R/W
2519 hex 2518 hex
2nd Motor Parameter L
H222
(HIGH)
R/W
1 to 65535
0.01
[mH]
251A hex 2519 hex
H222
(LOW)
R/W
251B hex 251A hex
2nd Motor Parameter Io
H223
(HIGH)
R/W
1 to 65535 0.01 [A]
251C hex 251B hex
H223
(LOW)
R/W
251D hex 251C hex
2nd Motor Parameter J
H224
(HIGH)
R/W
1 to 9999000
0.001
[kg/m
2
]
251E hex 251D hex
H224
(LOW)
R/W
251F to
2523 hex
Not used
2524 hex 2523 hex
2nd Motor Parameter R1
(Auto-tuning Data)
H230
(HIGH)
R/W
1 to 65535 0.001 [Ω]
2525 hex 2524 hex
H230
(LOW)
R/W
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution

Table of Contents