8 Communications Functions
8 - 80
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Sets multi-function input terminal status.
Transmission Frame
Command 02
Frame format
STX Station
No.
Command Data BCC CR
Description Data size Setting
STX Control code (Start of Text) 1 byte STX (0x02)
Station
No.
Station No. of target Inverter 2 bytes 01 to 32, and FF (Broadcast to all stations)
Command
Transmission command 2 bytes 02
Data Transmission data 16 bytes *(Refer to the next page.)
BCC Block check code 2 bytes
Exclusive OR of frame segments from
Station No. to Data (Refer to page 8-94.)
CR Control code (Carriage Return) 1 byte CR (0x0D)