EasyManua.ls Logo

Omron RX Series - Page 569

Omron RX Series
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 - 93
8 Communications Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
8-6 ASCII Method
8
8-6-2 Communications Commands
<Negative Response>
Response frame
*1 Error Code List
Frame format
STX Station No. NAK Error code BCC CR
Description Data size Setting
STX Control code (Start of Text) 1 byte STX (0x02)
Station No. Station No. of target Inverter 2 bytes 01 to 32
NAK
Control code (Negative
AcKnowledge)
1 byte NAK (0x15)
Error code Communications error status 2 bytes
*1
BCC Block check code 2 bytes
Exclusive OR of frame segments from
Station No. to Data (Refer to page 8-94.)
CR Control code (Carriage Return) 1 byte CR (0x0D)
Error code Description
01 H Parity error
02 H Checksum error
03 H Framing error
04 H Overrun error
05 H Protocol error
06 H ASCII code error
07 H Receiving buffer overrun error
08 H Receiving timeout error
– –
– –
11 H Command invalid error
12 H
13 H Execution disabled error
14 H
15 H
16 H Parameter invalid error
17 H
During a broadcast to all stations, the inverter sends back no response.