2 Design
2 - 28
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
400-V class
Model
Heavy/
Light
load
mode
Max.
applicable
motor
capacity
[kW]
Rated
input
current
[A]
Power cable
[mm
2
]
R, S, T, U, V, W,
+1, P/+2, N/–
Ground
cable
[mm
2
]
External
braking
resistor
between +1
and RB [mm
2
]
Terminal
screw
size
Crimp
terminal
Tightening
torque [N·m]
Molded
case
circuit
breaker
(MCCB)
3G3RX-A4004-V1
Heavy
load
0.4 1.8 1.25 1.25 1.25 M4 1.25-4 1.2 (1.8 max.) 5 A
Light
load
0.75 2.1 1.25 1.25 1.25 1.25-4 5 A
3G3RX-A4007-V1
Heavy
load
0.75 2.8 1.25 1.25 1.25 M4 1.25-4 1.2 (1.8 max.) 5 A
Light
load
1.5 4.3 2 2 2 2-4 10 A
3G3RX-A4015-V1
Heavy
load
1.5 4.2 2 2 2 M4 2-4 1.2 (1.8 max.) 10 A
Light
load
2.2 5.9 2 2 2 2-4 10 A
3G3RX-A4022-V1
Heavy
load
2.2 5.8 2 2 2 M4 2-4 1.2 (1.8 max.) 10 A
Light
load
3.7 8.1 2 2 2 2-4 15 A
3G3RX-A4037-V1
Heavy
load
3.7 9.8 2 2 2 M4 2-4 1.2 (1.8 max.) 15 A
Light
load
5.5 13.3 3.5 3.5 3.5 R2-4 30 A
3G3RX-A4055-V1
Heavy
load
5.5 15 3.5 3.5 3.5 M5 R2-5 2.4 (4.0 max.) 30 A
Light
load
7.5 20 3.5 3.5 3.5 3.5-5 30 A
3G3RX-A4075-V1
Heavy
load
7.5 21 3.5 3.5 3.5 M5 3.5-5 2.4 (4.0 max.) 30 A
Light
load
11 24 5.5 5.5 5.5 R5.5-5 50 A
3G3RX-A4110-V1
Heavy
load
11 28 5.5 5.5 5.5 M6 R5.5-6 4.0 (4.4 max.) 50 A
Light
load
15 32 8 8 5.5 R8-6 60 A
3G3RX-A4150-V1
Heavy
load
15 35 8 8 8 M6 8-6 4.5 (4.9 max.) 60 A
Light
load
18.5 41 14 14 8 R14-6 60 A
3G3RX-A4185-V1
Heavy
load
18.5 42 14 14 14 M6 14-6 4.5 (4.9 max.) 60 A
Light
load
22 47 14 14 14 R14-6 75 A
3G3RX-A4220-V1
Heavy
load
22 53 14 14 14 M6 14-6 4.5 (4.9 max.) 75 A
Light
load
30 63 22 22 14 R22-6 100 A
3G3RX-A4300-V1
Heavy
load
30 64 22 22 – M6 22-6 4.5 (4.9 max.) 100 A
Light
load
37 77 38 22 – 38-6 100 A