Chapter 5 Maintaining Your Library
Maintenance Actions
Scalar i2000 User’s Guide 292
Calibration Offsets 5
The calibration offsets graphical report shows the results for tests of tape
magazine, drive sled, and I/E station offsets compared to predefined
tolerances. Reports are generated for drive-side and door-side for all
frames.
• If the graphical report shows a failed result for one or more tape
magazines, make sure the magazines at the location of the failure are
installed properly and that the calibration targets are correctly
snapped on to the magazines.
• If the graphical report shows a failed result for the I/E station, make
sure the I/E station and front door are completely shut.
• If running the test again still generates failed results, realign the
middle X-axis rail and check the alignment of the top and bottom X-
axis rails at the location of the failure.
See figure 25 on page 293.