Chapter 2 Troubleshooting Your Library
Interpreting LEDs
Scalar i2000 User’s Guide 69
Table 13 LBX LED Version 03
Interpreting Power
Supply LEDs 2
Power supply problems are reported in tickets. To physically identify a
power supply, note the power supply number and module number in the
ticket details. Modules can have up to two power supplies each. The top
supply is #1 and the bottom supply is #2.
LED On/Off Combinations
Explanation1 2 3 4 5 6
Off Off Off Off Off Off Robotics are disabled, the access door is open, or the LBX
terminator is misaligned.
On Off Off Off Off Off The library has one control module and no expansion modules.
On Off Off On Off Off The library has one control module and one expansion module.
On Off Off On On Off The library has one control module and two expansion modules.
On Off Off On On On The library has one control module and three expansion modules.
On Off Off Off On On The library has one control module and four expansion modules.
On Off Off On Off On The library has one control module and five expansion modules.
On Off Off Off On Off The library has one control module and six expansion modules.
On Off Off Off Off On The library has one control module and seven expansion modules.
Note
The library can be physically configured to include
up to seven expansion modules. If any of the
expansion modules include drives, those modules
also will have power supplies.

Table of Contents

Other manuals for Quantum Scalar i2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i2000 and is the answer not in the manual?

Quantum Scalar i2000 Specifications

General IconGeneral
BrandQuantum
ModelScalar i2000
CategoryStorage
LanguageEnglish

Related product manuals