Chapter 5 Maintaining Your Library
Maintenance Actions
Scalar i2000 User’s Guide 296
Get/Put 5The get/put graphical report shows the results for tests of the
picker assembly while performing one get and one put function for each
tape magazine. The picker will use the selected scratch tape or the existing
tape if it finds one at the target.
• If the graphical report shows a failed result for one or more tape
magazines, make sure the magazines at the location of the failure are
installed properly.
• If there are multiple marginal results in an area, review the area to
make sure it is not prone to problems. Also run the library alignment
test (part of the installation verification or partial frame test) to make
sure the library is level.
• If there are a large number of issues, use rubbing alcohol to clean the
picker fingers and the detents in the side of the tapes.
• If the problems persist, you may need to replace the picker assembly.
See figure 27 on page 297.