Command reference
R&S
®
ZNL/ZNLE
582User Manual 1178.5966.02 ─ 20
MMEMory:SELect:CHANnel[:ITEM]:SPECtrogram............................................................ 583
MMEMory:SELect:CHANnel[:ITEM]:SGRam.....................................................................583
MMEMory:SELect[:ITEM]:SPECtrogram...........................................................................584
MMEMory:SELect[:ITEM]:SGRam................................................................................... 584
MMEMory:SELect:CHANnel[:ITEM]:TRACe[:ACTive].........................................................584
MMEMory:SELect[:ITEM]:TRACe<1...3>[:ACTive].............................................................584
MMEMory:SELect:CHANnel[:ITEM]:TRANsducer:ALL....................................................... 584
MMEMory:SELect[:ITEM]:TRANsducer:ALL......................................................................584
MMEMory:SELect:CHANnel[:ITEM]:ALL
MMEMory:SELect[:ITEM]:ALL
This command includes all items when storing or loading a configuration file.
The items are:
Hardware configuration: MMEMory:SELect[:ITEM]:HWSettings on page 582
Limit lines: MMEMory:SELect[:ITEM]:LINes:ALL on page 583
Spectrogram data: MMEMory:SELect[:ITEM]:SGRam on page 584
Trace data: MMEMory:SELect[:ITEM]:TRACe<1...3>[:ACTive]
on page 584
Transducers: MMEMory:SELect[:ITEM]:TRANsducer:ALL on page 584
Example:
MMEM:SEL:ALL
MMEMory:SELect:CHANnel[:ITEM]:DEFault
MMEMory:SELect[:ITEM]:DEFault
This command selects the current settings as the only item to store to and load from a
configuration file.
MMEMory:SELect:CHANnel[:ITEM]:HWSettings <State>
MMEMory:SELect[:ITEM]:HWSettings <State>
This command includes or excludes measurement (hardware) settings when storing or
loading a configuration file.
Measurement settings include:
general channel configuration
measurement hardware configuration including markers
limit lines
Note that a configuration may include no more than 8 limit lines. This number
includes active limit lines as well as inactive limit lines that were used last.
Therefore the combination of inactivate limit lines depends on the sequence of use
with MMEMory:LOAD:STATe on page 585.
color settings
configuration for the hardcopy output
Common instrument commands