R&S
®
ZVA / R&S
®
ZVB / R&S
®
ZVT Command Reference
SCPI Command Reference
Operating Manual 1145.1084.12 – 30 923
[SENSe<Ch>:]PULSe:GENerator<gen_no>:DINCrement <Increment>
Defines a delay increment for the sync signal in chopped pulse profile mode. The delay increment defines
the distance between two measurement intervals (sweep points). For sweep point no. n, the total delay of
the sync signal relative to the pulse generator signal is <Delay> + n * <Increment>.
This parameter is not available in manual control.
Number of the pulse generator signal. This suffix must be set to 1, the command
is generall.
0 s to +0.8191875 s [s]. UP and DOWN increment/decrement the delay in 12.5
ns steps. A zero delay disables the chopped pulse profile mode.
Device-specific, command or query
See [SENSe<Ch>:]PULSe:GENerator<gen_no>:CPProfile
[SENSe<Ch>:]PULSe:GENerator<gen_no>:MCHannel <Channel>
Selects the master channel for CONTinuous pulse mode.
Channel number.
This Parameter is ignored, the setting affects all channels.
Number of the pulse generator signal. This parameter is ignored, the setting
affects both signals.
Master Channel.
The settings of the master channel are used for all channels.
Channel-specific pulse generator settings for other channels are not overwritten.
If Mode is changed to CSP they are used again.
1...Max channel number.
It is recommended to use channel 1.
Device-specific, command or query
See [SENSe<Ch>:]PULSe:GENerator<gen_no>:DELay
[SENSe<Ch>:]PULSe:GENerator<gen_no>:MODE CSPecific | CONTinuous
Selects the channel-specific or continuous pulse mode.
Channel number.
This Parameter is ignored, the setting affects all channels.
Number of the pulse generator signal. This parameter is ignored, the setting affects
both signals.