SERVICE PROGRAM MODE 26 July 2002
5-12
2
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Paper Trans_NN1 (Paper Transfer NN1)
NN1: Absolute humidity AH (g/m
3
) is 8.0 < AH 14
The display indicates: Paper Weight/Side 1 or 2/Paper Width (mm)
Nrml: Thin paper, Mid: Normal plain paper, Thk: Thick paper
1 Normal/1st/-297
Sets the paper transfer current for the ‘NN1’ humidity
range. See SP2-310 for comments.
[0 ~ 70.0 / 40.0 / 0.1 µA/step]
2 Normal/1st/257-296
[0 ~ 70.0 / 42.0 / 0.1 µA/step]
3 Normal/1st/210-256
[0 ~ 70.0 / 44.0 / 0.1 µA/step]
4 Normal/1st/129-209
[0 ~ 70.0 / 47.0 / 0.1 µA/step]
5 Normal/1st/-128
[0 ~ 70.0 / 50.0 / 0.1 µA/step]
6 Middle/1st/-297
[0 ~ 70.0 / 41.0 / 0.1 µA/step]
7 Middle/1st/257-296
[0 ~ 70.0 / 43.0 / 0.1 µA/step]
8 Middle/1st/210-256
[0 ~ 70.0 / 45.0 / 0.1 µA/step]
9 Middle/1st/129-209
[0 ~ 70.0 / 47.0 / 0.1 µA/step]
10 Middle/1st/-128
[0 ~ 70.0 / 51.0 / 0.1 µA/step]
11 Thick/1st/-297
[0 ~ 70.0 / 23.0 / 0.1 µA/step]
12 Thick/1st/257-296
[0 ~ 70.0 / 23.0 / 0.1 µA/step]
13 Thick/1st/210-256
[0 ~ 70.0 / 24.0 / 0.1 µA/step]
14 Thick/1st/129-209
[0 ~ 70.0 / 24.0 / 0.1 µA/step]
15 Thick/1st/-128
[0 ~ 70.0 / 24.0 / 0.1 µA/step]
16 Normal/2nd/-297
[0 ~ 70.0 / 42.0 / 0.1 µA/step]
17 Normal/2nd/257-296
[0 ~ 70.0 / 45.0 / 0.1 µA/step]
18 Normal/2nd/210-256
[0 ~ 70.0 / 48.0 / 0.1 µA/step]
19 Normal/2nd/129-209
[0 ~ 70.0 / 51.0 / 0.1 µA/step]
20 Normal/2nd/-128
[0 ~ 70.0 / 55.0 / 0.1 µA/step]
21 Middle/2nd/-297
[0 ~ 70.0 / 43.0 / 0.1 µA/step]
22 Middle/2nd/257-296
[0 ~ 70.0 / 46.0 / 0.1 µA/step]
23 Middle/2nd/210-256
[0 ~ 70.0 / 49.0 / 0.1 µA/step]
24 Middle/2nd/129-209
[0 ~ 70.0 / 52.0 / 0.1 µA/step]
25 Middle/2nd/-128
[0 ~ 70.0 / 56.0 / 0.1 µA/step]
26 Thick/2nd/-297
[0 ~ 70.0 / 23.0 / 0.1 µA/step]
27 Thick/2nd/257-296
[0 ~ 70.0 / 28.0 / 0.1 µA/step]
28 Thick/2nd/210-256
[0 ~ 70.0 / 32.0 / 0.1 µA/step]
29 Thick/2nd/129-209
[0 ~ 70.0 / 37.0 / 0.1 µA/step]
30 Thick/2nd/-128
[0 ~ 70.0 / 42.0 / 0.1 µA/step]
31 OHP/297
[0 ~ 70.0 / 22.0 / 0.1 µA/step]
312*
32 OHP/210
[0 ~ 70.0 / 30.0 / 0.1 µA/step]
Paper Trans_NN2 (Paper Transfer NN2)
NN2: Absolute humidity AH (g/m
3
) is 14 < AH 19
The display indicates: Paper Weight/Side 1 or 2/Paper Width (mm)
Nrml: Thin paper, Mid: Normal plain paper, Thk: Thick paper
1 Normal/1st/-297
Sets the paper transfer current for the ‘NN2’ humidity
range. See SP2-310 for comments.
[0 ~ 70.0 / 36.0 / 0.1 µA/step]
2 Normal/1st/257-296
[0 ~ 70.0 / 38.0 / 0.1 µA/step]
3 Normal/1st/210-256
[0 ~ 70.0 / 39.0 / 0.1 µA/step]
313*
4 Normal/1st/129-209
[0 ~ 70.0 / 40.0 / 0.1 µA/step]