SERVICE PROGRAM MODE 26 July 2002
5-62
7
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Toner End Counter Clear
1 K Toner
2 C Toner
3 M Toner
4 Y Toner
923
100 All
Clears the toner end counter (SP7-922).
The machine goes back to the normal operation mode if
the toner end counter is cleared.
Charger Clean Counter 924
1
Charger Clean
Counter
Displays how many times the charge corona wire has
been cleaned.
[0 ~ 9999999 / 0 / 1 sheet/step]
SP7-926 resets the counter.
Time Counter Display 925
1 Time Counter Display
Displays the current counter of the charge corona unit
cleaning interval.
SP2-801 specifies the charge corona unit cleaning
interval.
Charger Cleaner Counter Reset 926
1
Charger Cleaner
Counter Reset
Resets the charge wire cleaner counter (SP7-924).
Timer Counter Clear 927
1
Clears the counter of the charge corona unit cleaning
interval.
SP7-927 clears the counter displayed by SP7-925, but
does not clear the value specified with SP2-801.
Previous PM Counter Clear 928
1
Previous PM Counter
Clear
Clears the previous PM counter (SP7-906).
Replace Counter Clear 929
1 Replace Counter Clear Clears the replace counter.
Counter For Designer
1
Counter 1 For
Designer
930
2
Counter 2 For
Designer
DFU
SP9-XXX: (Etc.)
9
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Discharge Threshold 904
1 Discharge Threshold
[90 ~ 220 / 150 / 0.1 g/m
3
/step]