Analog modulations
R&S
®
SMB100B
93User Manual 1178.3711.02 ─ 08
You can create the file internally in the table editor or externally.
●
To select an existing file, select "Select List > navigate to the file *.pulstrn > Select"
●
Use the general editor function to create internally new file or to edit an existing
one.
●
Use the standard file manager function to load externally created files to the instru-
ment.
Remote command:
[:SOURce<hw>]:PULM:TRAin:CATalog? on page 434
[:SOURce<hw>]:PULM:TRAin:SELect on page 435
[:SOURce<hw>]:PULM:TRAin:DELete on page 434
Edit Pulse Train Data
Accesses the build-in table editor to define a new pulse train file or edit an existing one.
"On-Time, µs/Off-Time,µs"
Sets the pulse on and pulse off time.
"Count"
Sets the number of repetitions of an "On-/ Off-Time" value pair.
Pulses with "Count = 0" are ignored.
Use this method to skip value pairs temporarily, without deleting them
from the table.
Remote command:
[:SOURce<hw>]:PULM:TRAin:ONTime on page 434
[:SOURce<hw>]:PULM:TRAin:OFFTime on page 434
[:SOURce<hw>]:PULM:TRAin:REPetition on page 435
[:SOURce<hw>]:PULM:TRAin:DELete on page 434
Data handling keys
Standard functions for file and data handling.
Note: Save a list only after filling both columns (frequency and level), otherwise the
entries are lost.
Go To ← Data handling keys
Selects a row for editing.
Edit ← Data handling keys
Enables you to insert, or delete a row or ranges within a list, and provides access to a
dialog for automatic filling.
See "Fill..." on page 93.
Save As/Save ← Data handling keys
Saves the list in a file with user-defined name and predefined file extension. To save a
copy or create a file, use the "Save as" function.
Fill...
Provides parameters for filling a table automatically with user-defined values.