Instrument Function
R&S
®
SMBV100A
274Operating Manual 1176.8016.02 ─ 17
"Ext Gated"
The pulse generator signal is gated by an external gate signal.
Example: Generation of pulse signals using trigger mode Exter-
nal Gated (Single Pulse)
The measurement is performed using a 6-dB-attenuator.
Parameter Value
Trigger Mode Extern Gated
Double Pulse State Off
External Trigger Input Slope Positive
Pulse Delay 100 ns
Pulse Width 100 ns
Pulse Period 300 ns
Channel 1 = Indicates the external gate signal. The signal is active when it is high
(positive).
Channel 2 = Indicates the sync signal. The sync signal starts after a trigger delay of
typically 50 ns (see specifications). It is repeated after the set pulse period
of 300 ns as long as the gate signal is active.
Channel 3 = Indicates the pulse signal. The first pulse starts after the pulse delay of
100 ns. The second pulse starts after the set pulse period.
Remote command:
[:SOURce<hw>]:PULM:TRIGger:MODE on page 802
External Trigger Input Slope - Pulse Generator
(External Trigger only)
Sets the polarity of the active slope of an applied trigger signal.
"Positive"
The pulse generator is triggered on the positive slope of the external
trigger signal.
"Negative"
The pulse generator is triggered on the negative slope of the external
trigger signal.
Remote command:
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe on page 802