Remote Control Commands
R&S
®
SMBV100A
745Operating Manual 1176.8016.02 ─ 17
Manual operation: See "Ext. Trigger Input Slope" on page 141
[:SOURce]:INPut:DELay:ADCState <State>
Enables/disables the automatic delay compensation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 1
Example: see example for [:SOURce]:INPut:DELay:CLENgth<ch>
on page 745
Manual operation: See "Automatic Delay Compensation" on page 141
[:SOURce]:INPut:DELay:SPOSition <Position>
Defines the position of the slave instrument in the daisy chain. The slave directly con-
nected to the master instrument is the one with number 1.
Parameters:
<Position> integer
Range: 1 to 10
*RST: 1
Example: see example for [:SOURce]:INPut:DELay:CLENgth<ch>
on page 745
Manual operation: See "Automatic Delay Compensation" on page 141
[:SOURce]:INPut:DELay:CLENgth<ch> <CableLength>
Sets the total length of the cable used to connect the CLK OUT and CLK IN connec-
tors. For the first slave in the chain, the value represents the cable length between the
master and the first slave; for the second slave, the cable length to the first and to the
second has to be defined, etc.
Parameters:
<CableLength> float
Range: 0 to 10
Increment: 0.01
*RST: 0.5
Example: Setting in the first slave instrument Slave#1:
:SOURce:INPut:DELay:SPOSition 1
:SOURce:INPut:DELay:CLENgth1 1
:SOURce:INPut:DELay:ADCState ON
SOURce Subsystem