EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Page 760

Rohde & Schwarz SMBV100A
911 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
745Operating Manual 1176.8016.02 ─ 17
Manual operation: See "Ext. Trigger Input Slope" on page 141
[:SOURce]:INPut:DELay:ADCState <State>
Enables/disables the automatic delay compensation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 1
Example: see example for [:SOURce]:INPut:DELay:CLENgth<ch>
on page 745
Manual operation: See "Automatic Delay Compensation" on page 141
[:SOURce]:INPut:DELay:SPOSition <Position>
Defines the position of the slave instrument in the daisy chain. The slave directly con-
nected to the master instrument is the one with number 1.
Parameters:
<Position> integer
Range: 1 to 10
*RST: 1
Example: see example for [:SOURce]:INPut:DELay:CLENgth<ch>
on page 745
Manual operation: See "Automatic Delay Compensation" on page 141
[:SOURce]:INPut:DELay:CLENgth<ch> <CableLength>
Sets the total length of the cable used to connect the CLK OUT and CLK IN connec-
tors. For the first slave in the chain, the value represents the cable length between the
master and the first slave; for the second slave, the cable length to the first and to the
second has to be defined, etc.
Parameters:
<CableLength> float
Range: 0 to 10
Increment: 0.01
*RST: 0.5
Example: Setting in the first slave instrument Slave#1:
:SOURce:INPut:DELay:SPOSition 1
:SOURce:INPut:DELay:CLENgth1 1
:SOURce:INPut:DELay:ADCState ON
SOURce Subsystem