Remote Control Commands
R&S
®
SMBV100A
750Operating Manual 1176.8016.02 ─ 17
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
IQ:OUTP:BIAS:ANAL:COUP ON
activates I/Q bias coupling.
Manual operation: See "Couple IQ Bias" on page 318
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:I <I>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:Q <Q>
Specifies the amplifier bias of the respective I/Q- component.
Parameters:
<Q> float
Range: -3.6 to 3.6
Increment: 0.002
*RST: 0
Example:
IQ:OUTP:ANAL:BIAS:Q 0.1 V
sets a bias of 100 mV for the Q-signal.
Manual operation: See "Bias (EMF)" on page 318
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:OFFSet:I <I>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:OFFSet:Q <Q>
Valid only for output type Differential (IQ:OUTP:ANAL:TYPE DIFF).
Sets an offset between the inverting and non-inverting output.
Parameters:
<Q> float
Range: -0.3 to 0.3
Increment: 1E-4
*RST: 0
Example:
IQ:OUTP:ANAL:TYPE DIFF
the I/Q-signal components are output differential
:IQ:OUTP:ANAL:OFFS:Q 0.05 V
sets an offset of 50 mV for the I-signal.
Manual operation: See "Offset (EMF)" on page 319
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:OPTimization[:RF]:STATe <State>
Activates/deactivates optimization of level accuracy and imbalance for RF Output.
Level accuracy and imbalance can be either optimized for RF output (active) or for dif-
ferential outputs (not active).
SOURce Subsystem