KodescriptPlus Warnings (cont'd)
Code Description Explanation
31 Incorrect bar code data
length
The number of characters to be encoded in the bar
code exceeds the maximum number of characters
permitted for that bar code.
32 Specified value not in
range
The command includes a value outside the valid range
of values for the command.
33 Horizontal Spread not
terminated
The Buffer Store Variable Data command (^]), which
must be used in conjunction with the Horizontal Spread
command (^Snniip^-), was not detected.
34 Column value exceeded
range
While using the (^Cnn^-) command, the
KodescriptPlus document includes a column number
that exceeds the maximum number of columns
permitted for the document.
35 Invalid KodescriptPlus
Data Terminator
command
The command includes a Data Terminator command
other than (^FF^-), (^Fn^-), (^FR^-), (^G^-), or
(^Rnnnnnn^-).
36 Data Terminator
command – illegal
character
The Data Terminator command includes a character
other than a white (transparent) character or a control
character.
37 Sectional Increment/
Decrement command
(IDSaCb±c) error
Either an illegal parameter value has been detected or
the maximum number of 5 incremental/decremental
sections has been exceeded.
38 An unknown format
type has been coded
The format type specified by the Modify Data command
(^Mdaa) cannot be found in the list of format types
available.
39 Incorrect/Unknown
multi-functional bar
code command error
The "S" parameter of the (^Mbaa) (Hbbb) (Wccc)
(Od) (Re) (Nf) (Fg) (Ihi) (Ej) (Ck1) (Bm) (S)
either contains an unsupported bar code type or is
incorrectly formatted.