LP 100R Laser Printer Operator's Guide Chapter 5: Problem Solving
Rev: 1 Page 5-28 April, 2014
of 30 pages
KodescriptPlus Errors
Code Description Explanation
51 Excessive number of fields The number of defined fields exceeds the maximum
number permitted (499).
52 Excessive number of Hard
Data fields
The number of defined Hard Data fields exceeds the
maximum number permitted (99).
53 Excessive number of Line
fields
The number of Line fields exceeds the maximum
number permitted (99).
54 Excessive number of
Reverse Image fields
The number of Reverse Image fields exceeds the
maximum number permitted (49).
55 Excessive number of link
fields within a field
The number of fields being linked within a field
exceeds the maximum number permitted (5).
56 Undetermined link field
Hard Data length
The terminating Hard Data Delimiter was not
detected, which means that the length cannot be
determined.
57 Cannot open file for reading
Occurs when a PCX file is specified in a
KodescriptPlus file but is not found in the controller.
58 Cannot open file for writing An error has occurred while writing a PCX file to the
controller. This file will be corrupted.
59 Unable to write to file The file created by the program is corrupted.
60 Distorted PCX file The PCX file is corrupt. One possible cause is the
use of a color PCX file.
61 Number of defined fields
greater than supplied data
The number of fields coded as part of the
KodescriptPlus program is greater than the number
of data fields to be printed.
62 Defined fields less than
supplied data
The amount of data supplied exceeds the number
of fields coded as part of the KodescriptPlus
program.
63 Command/data not
correctly terminated
The buffer does not contain an appropriate
terminating character.
64 Invalid Field Number
character
The Field Number includes an invalid character.
65 Invalid Repeat Count The Repeat Count includes an invalid character.
66 Data Condensing error The number of characters to be printed in a field
that is associated with the Data Condensing On
command (^f01^-) exceeds the number of
characters specified for that field.