Power Requirements
200-240 AC volts
30 Amps
50/60 Hz
Single phase
Termination
- The United States requires a NEMA L6-30R (Twist Lock).
- Other countries should replace the line cord at the Connector Panel Input
Power Supply to match the electrical codes of that country.
Power Source
The power source should not exceed the voltage/frequency fluctuations as
indicated below:
Voltage fluctuations – 200 to 240 VAC ± 10%
Frequency fluctuation – 50/60 Hz ± 3%
Temperature/Relative Humidity
The following environment is required for consistent printer performance:
Temperature – 50°–95°F (10°–35°C) with a temperature variation not
exceeding 18°F (10°C)
Relative humidity – 35% to 80% with a humidity variation not exceeding
20% to RH per hour