LP 100R Laser Printer Operator's Guide Chapter 5: Problem Solving
Rev: 1 Page 5-29 April, 2014
of 30 pages
KodescriptPlus Errors (cont'd)
Code Description Explanation
67 Link field data length. The amount of data supplied for a specific link field
exceeds the amount of data specified.
68 Field number being linked
does not exist.
The program cannot find a field number that was to
be linked.
69 Maximum number of AIs
(Application Identifications)
has been exceeded.
The data stream for a UCC/EAN 128 bar code
contains more than 4 allowable AIs.
70 Maximum length allowed for
a variable-length AI has
been exceeded.
A variable-length AI that contains more than the
maximum number of characters allowed has been
included in a UCC/EAN 128 bar code.
71 Maximum Length allowed
for a fixed-length AI has
been exceeded.
A variable-length AI that contains less than or more
than the maximum number of characters allowed
has been included in a UCC/EAN 128 bar code.
72 An invalid or unrecognized
AI has been detected.
The data stream for a UCC/EAN 128 bar code
contains an AI that cannot be found in the
specification list for this bar code.

Table of Contents