231
Smart Camera / Vision-Sensor / 1D-/2D-Code-Scanner / OCR Reader
Version Release
date
Description / changes Compatibility
1.2.0 23.02.15 Minor release.
Features:
Device Camera: New image acquisition is independent
from the algorithm processing as long the image buffer (10
images) does have free capacity.
Device Camera: Illumination setting can be linked (Light
Internal, Light External)
Device Camera: ProfiNet Trigger
Device Communication (Digital Output): Forced to the
enhancements in the Device Camera the "Ready"
digital output is no longer supported the way it was in
earlier versions. New flags "Process" and "Capture" are
available in new projects. If you load a version 1.1.x
or earlier in the sensor, the deprecated "Ready" output
keeps in the project tree as is. In this case the sensor
hardware signals the "Ready" flag as a "Process" flag!
Device Display: Linking the I/O states to the Device Display
Device IO Unit: Project change by digital I/O control
Module Code 1D: Property "Read Timeout" unit changed
from [s] to [ms]. Conversion is automatically done if
needed.
Module Code 1D: Advanced settings
Module Code 2D: Property "Read Timeout" unit changed
from [s] to [ms]. Conversion is automatically done if
needed.
Projects: 1.2.x /
1.2.x
PC Software:
1.2.x / 1.2.x