33
Smart Camera / Vision-Sensor / 1D-/2D-Code-Scanner / OCR Reader
6.13. Password
Password protection prevents inadvertent changes to selected settings.
Password
Activating the password function
De/activate
Change
Back
Run
De/activate: Activate or deactivate password protection. When password
protection is activated, the sensor is automatically disabled after
pressing any in the “Run” mode.
Change: Change the password.
If the password function is active, the password must be entered each time the sensor is operated. After the
password has been correctly entered with the “+” and “–” keys, the menu is enabled and the sensor can be
operated.
• The password function is deactivated upon shipment from the factory.
• Passwords can be selected within a range of 0000 to 9999.
Be sure to make a note of the new password before exiting the “change password” function! If the password
is forgotten, it must be overwritten with a master password. The master password can be requested by e-mail
from support@wenglor.com.
6.14. Status Information
In addition to status information and warnings in the “Info” menu, messages are also displayed as symbols in
the run window.
weQube
Critical Error
A critical error has occurred.
weQube 0x01
Fatal Error
A fatal error has occurred. The sensor must be restarted.