Software Module
11.4.2. Settings
Image Area
The coordinate system set up by means of the specified method is displayed.
Property
The following settings/results appear.
Process Time Sensor processing time for the process steps in the localizer
module
Module State Error codes to give support in error diagnosis. (see section 18.5)
Input Image Selection of the channel for the image input
Construction
Method
The coordinate system can be set up in different ways:
1 point origin
One point defines the origin of
the translatory/rotary coordinate
system.
1 point X-axis, 1 point
Y-axis
One point defines the X-axis and
one defines the Y-axis, by means
of which a translatory coordinate
system is created.
1 point origin,
1 point X-axis
One point defines the origin and
one point defines the X-axis of
the translatory/rotary coordinate
2 points X-axis, 1 point
Y-axis
Two points define the X-axis and
one point defines the Y-axis of
the translatory/rotary coordinate
system
Tracking Method The way in which the points should be tracked can be specified.
No
The points are not tracked.
Yes
The points are tracked in the X
and Y directions.
Horizontally
The points are only tracked in
the X direction.
Vertically
The points are only tracked in
the Y direction.
Tracking Point:
Only available if the Construction Method uses more than one
point.
1. Pt.: Tracking of all points related to this point 1.
2. Pt.: Tracking of all points related to this point 2.
3. Pt. (if available): Tracking of all points related to this point 3."