P1086708-001 ZXP Series 9 Card Printer Service Manual 371
Replacement Procedures for the Laminator
Procedures: Top Laminator Control Motor
Top Laminator Control Motor
For replacement, use Kit Mtr Bi-Stp PM42L-048 RGT 8 105936G-512. Contact Zebra Customer
Service at +01 877-275-9327 for ordering information.
Step 1. With a TORX T10 driver, remove the two screws holding the top laminator control
motor in place. Note that the left screw connects a ground wire.
Step 2. If not already disconnected, disconnect the motor plug from J17.
Step 3. Cut the associated cable ties, and remove the top laminator control motor.