Performance ParametersPerformance Parameters
ParameterParameter
NameName
PDHPDH SDH, SONETSDH, SONET OTNOTN
G.821G.821 G.826G.826 M.2100M.2100
G.826,G.826,
G.828+G.829, G.828+G.829,
M.2101.1M.2101.1
G.8201,M.2401G.8201,M.2401
ES
SES
BBE
ALS
UAT
*
UNAV
AVT
EFS
*: "UAS" is displayed.
OTN-relatedOTN-related
These items appear if OTN TxOTN Tx and OTN RxOTN Rx are selected on Setup screen.
OTNOTN
G.8201, M.2401 (M.2110)
Time periodTime period
15 minutes, 1 hour, 2 hours, 24 hours, 7 days
AllocationAllocation
Touching the SetupSetup button launches the dialog box. Refer to Performance
Parameters in "OTN Application" .
SDH/SONET-relatedSDH/SONET-related
These items appear if SDH TxSDH Tx and SDH RxSDH Rx, or SONET TxSONET Tx and SONET RxSONET Rx are
selected on Setup screen.
SDH/SONETSDH/SONET
G.826, G.828+G.829, M.2101.1(M.2100)
Time periodTime period
15 minutes, 1 hour, 2 hours, 24 hours, 7 days
Allocation [%]Allocation [%]
Set the allocation ratio of the performance objectives defined in ITU
Rrecommendation.
For G.826 and G.828+G.829, the PO limits used for Pass/Fail judgement are
calculated by multiplying the allocation by the performance objectives of ITU
Recommendation.
For M2101.1(M.2100), the PO limits are calculated by multiplying the
allocation and Time period (unit in seconds) by the performance objectives of
ITU Recommendation.