Preset dataPreset data
Tandem connectionTandem connection
Frequency OffsetFrequency Offset
Alarm InsertionAlarm Insertion
Error InsertionError Insertion
PointerPointer
OH Preset data
SOH : All bytes except B1, B2, H1, H2 and H3 byte
VC-4/VC-3 POH : All bytes except B3
VC-12/VC-11 POH : All bytes except BIP-2
Path trace Setting: J0, J1, J2 (ASCII data, 16 bytes/64 bytes)
Off, N1(VC-4), N1(VC-3), N2(VC-12), N2(VC-11)
±50 ppm 1 ppm step
Item
LOS, LOF, OOF, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-TIM, HP-PLM, HP-
UNEQ, HP-RDI, TU-AIS, TU-LOP, TU-LOM, LP-TIM, LP-UNEQ, LP-RDI, LP-
PLM, LSS, TC-UNEQ, TC-LTC, TC-TIM, TC-AIS, TC-RDI, TC-ODI
Insertion :
Permanent, Alternate (Excluding LOS, OOF and LSS)
Permanent (For LOS, OOF and LSS)
Alternate :
Alarm length : 1 to 8000 (Frame)
Normal length : 1 to 8000 (Frame)
Item
A1A2, B1, B2, MS-REI, B3, HP-REI, V5/B3, LP-REI, TC-IEC, TC-REI, TC-OEI,
TC-BIP-2, ERR-TRANS, Pattern error
Insertion :
Manual, Rate, Alternate (Excluding ERR-TRANS)
Manual, Rate (For ERR-TRANS)
Manual :
Burst length : 1 to 8000 (bit) (Excluding Pattern error)
Burst length : 1 to 4000 (bit) (For Pattern error)
Rate:
1*10
-3
, 1*10
-4
, 1*10
-5
, 1*10
-6
, 1*10
-7
, 1*10
-8
, 1*10
-9
, 1*10
-10
The available highest rate varies depending on the error item.
Alternate :
(Excluding Pattern error)
Error : 1 to 8000 (Frame)
Normal : 1 to 8000 (Frame)
(For Pattern error)
Error : 1 to 4000 (bit)
Normal : 100 to 4000 (bit)
AU-4, AU-3, TU-3, TU-12, TU-11