Section 8 Remote Control Commands
8-32
ESE3
ERR Event Status Enable Register
Setting error event status enable register
Function
Sets the error event status enable register. When the set error-event occurs, the end
summary bit (ESB, bit 3) of the status byte register becomes “1” (true)
Command
ESE3 register
Query
ESE3?
Response
register
Parameters
register Error event status enable register
Value = bit0 + bit1 + ... + bit7
When using W-CDMA, GSM or PDC measurement software
bit0 = 2
0
= 1 : Synchronization loss (bit error rate measurement)
bit1 = 2
1
= 2 : Not used
bit2 = 2
2
= 4 : Transmission measurement error
bit3 = 2
3
= 8 : Reception measurement error
bit4 = 2
4
= 16 : Call processing error
bit5 = 2
5
= 32 : Not used
bit6 = 2
6
= 64 : Call drop error
bit7 = 2
7
= 128 : Not used
When using CDMA2000 measurement software
bit0 = 2
0
= 1 : Not used
bit1 = 2
1
= 2 : Access Probe Power measurement error
bit2 = 2
2
= 4 : Transmission measurement error
bit3 = 2
3
= 8 : Reception measurement error
bit4 = 2
4
= 16 : Call processing error
bit5 = 2
5
= 32 : Not used
bit6 = 2
6
= 64 : Call drop error
bit7 = 2
7
= 128 : Not used
Description
From among the values 2
0
= 1, 2
1
= 2, 2
2
= 4, 2
3
= 8, 2
4
= 16, 2
5
= 32, 2
6
= 64, and 2
7
= 128, which correspond to bits 1, 2, 3, 4, 5, 6 and 7 of the error event status enable
register; the sum of values of bits desired to be enabled becomes the parameter.
Sample programming
To enable transmission measurement error and reception error events:
ESE3 12 /*Transmission error (2
2
= 4) + reception error (2
3
= 8)*/