7.6 Status Report
7-25
7.6.7 END event status enable register
Each bit of the END event status enable register corresponds to each bit of the END
status register. Logical OR of the bits is output to bit 2 of the status byte register.
That is, when any status specified by the END event status enable register has oc-
curred, bit 2 of the status byte register becomes 1 (true).
Setting
Set the END event status enable register by using the ESE2 command. The
parameter is the decimal number converted from the sum of the values obtained
by binary-weighing the specified bits.
Example:
To set bit 2 of the status byte register to 1 when measurement has been com-
pleted:
ESE2 1 /*Measurement completion is bit 0, so 20 = 1 is set.*/
Query
Read using the ESE2? query. Response is the decimal number converted from
the sum of the values obtained by binary-weighing the specified bits.
Clear
The following methods are available to clear the END event status enable register:
Send the ESE2 0 command