Section 8 Remote Control Commands
8-52
REMDISP
Remote Control Display Mode
Function
Sets error* processing mode during remote control.
* Indicates the errors that are displayed in the pop-up window. Measurement errors
and call processing errors are not included.
Command
REMDISP mode
Query
REMDISP?
Response
Mode
Parameter
mode Error processing mode during remote control
NORMAL: Normal mode (default)
When an error occurs, it ignores it and continues the subsequent
command processing. The pop-up window for the error is
displayed when the error occurs, it then disappears when the
subsequent command is processed.
REMAIN: Error remain mode
Displays the pop-up window for an error until another error
occurs. When an error occurs by processing the subsequent
command, a pop-up window for the error is displayed.
STOP: Stop mode
When an error occurs, it displays a pop-up window for it and
stops processing the subsequent command.
Description
This function is available only for remote control.
Sample programming
To stop processing when an error occurs during remote control:
REMDISP STOP
Error processing