8-9
8.1 Command List by Function
8.1.9 Parameter save commands
The commands for saving parameter settings are listed in the table below. The measurement screen of an activated phone can be
saved. This command is available on all screens.
Table 8-1-9-1 Parameter save commands
Function Command Query Response Remarks
Directory Path ----- SVCD? dir_path
File List ----- SVFLIST? num,a1,name1,a2,name2
,...,a(num),name(num)
num File Number
a Attribute
= 1 Archive or
2 Read Only
name Object Name
Default Name PRMSAVE ----- -----
File Name PRMSAVENAME fname ----- ----- fname File Name
Save Parameter
File Number PRMSAVE fnumber ----- ----- fnumber File Number
Default File Name Query ----- SVDEFFILE? fname fname File Name
8.1.10 Parameter read commands
The commands for reading files saved with parameter save commands are listed in the table below. This command is available
on all screens.
Table 8-1-10-1 Parameter read commands
Function Command Query Response Remarks
Directory Path ----- RLCD? dir_path
File List ----- RLFLIST? num,a1,name1,a2,name2
,...,a(num),name(num)
num File Number
a Attribute
= 1 Archive or
2 Read Only
name Object Name
File Name PRMRECALLNAME fname ----- ----- fname File NameRecall Parameter
File Number PRMRECALL fnumber ----- ----- fnumber File Number

Table of Contents