8.2 Command Specifications in Alphabetical Order
8-35
ESR3?
Standard Event Status Register Query
Reading the error event status register
Function
Reads the error event status register. The event that occurred can be identified with
the read value.
Command
None
Query
ESR3?
Response
register
Parameters
register Error event status register
Value = bit0 + bit1 + ... + bit7
When using W-CDMA, GSM or PDC measurement software
bit0 = 2
0
= 1 : Synchronization loss (bit error rate measurement)
bit1 = 2
1
= 2 : Not used
bit2 = 2
2
= 4 : Transmission measurement error
bit3 = 2
3
= 8 : Reception measurement error
bit4 = 2
4
= 16 : Call processing error
bit5 = 2
5
= 32 : Not used
bit6 = 2
6
= 64 : Call drop error
bit7 = 2
7
= 128 : Not used
When using CDMA2000 measurement software
bit0 = 2
0
= 1 : Not used
bit1 = 2
1
= 2 : Access Probe Power measurement error
bit2 = 2
2
= 4 : Transmission measurement error (excepting Access
Probe Power)
bit3 = 2
3
= 8 : Reception measurement error
bit4 = 2
4
= 16 : Call processing error
bit5 = 2
5
= 32 : Not used
bit6 = 2
6
= 64 : Call drop error
bit7 = 2
7
= 128 : Not used
Description
The parameter is the sum of the values 2
0
= 1, 2
1
= 2, 2
2
= 4, 2
3
= 8, 2
4
= 16, 2
5
= 32,
2
6
= 64, and 2
7
= 128, which correspond to bits 1, 2, 3, 4, 5, 6 and 7 of the error event
status enable register. When the Response is read, the error event status register is
cleared.
Sample programming
To read the end event status register:
ESR3?