AC and DC Parameters
7-8 Copyright © 2001, 2004 ARM Limited. All rights reserved. ARM DDI 0210C
Figure 7-6 Output 3-state time
The timing parameters used in Figure 7-6 are listed in Table 7-6.
Figure 7-7 Unidirectional data write cycle
The timing parameters used in Figure 7-7 are listed in Table 7-7.
MCLK
TBE
A[31:0]
D[31:0]
nRW
LOCK
nOPC
nTRANS
MAS[1:0]
T
tbz
T
tbe
Table 7-6 Output 3-state time timing parameters
Symbol Parameter Parameter type
T
tbe
Address and Data bus enable time from TBEr Maximum
T
tbz
Address and Data bus disable time from TBEf Maximum
MCLK
nENOUT
DOUT[31:0]
T
dohu
T
doutu
T
nen
Table 7-7 Unidirectional data write cycle timing parameters
Symbol Parameter Parameter type
T
dohu
DOUT[31:0] hold time from MCLKfMinimum
T
doutu
MCLKf to DOUT[31:0] valid Maximum
T
nen
MCLKf to nENOUT valid Maximum