3.1.1 DISPLAY ON INSTRUMENT PANEL
The MICOM unit determines the difference between the
max. engine speed without load when starting reaping
and the engine speed during reaping.
When the engine speed decreases, the No. 1, 2, 3 and
caution lamps come on in order. When the speed de-
creases below the specified level, all lamps blink. Re-
versely, the caution, No. 3, 2 and 1 lamps go out in order
if the engine load decreases and the difference between
the speed without load and the current speed decreases.
The max. engine speed with load when starting reaping is
detected by the electronic pick up device when the thresh-
ing clutch is engaged (threshing unit switch: ON) and the
straw sensor is ON from OFF before starting reaping.
3.1.2 COOLANT TEMPERATURE
GAUGE AND FUEL GAUGE
When the coolant temperature rises, the resistance of the
coolant temperature sensor drops to turn the coolant tem-
perature lamp ON. When the coolant temperature drops,
the resistance of the coolant temperature sensor rises
and the coolant temperature lamp goes off.