Diagnostic instruments
file:///D|/Manuales/Para%20recolocar/MOTOS/DUCATI/DUCATI/M796/wsm/EN/M796_ABS_11_6_13.36.1.html[11/12/2015 18:40:27]
If the measured current is a positive quantity, it means that generator is feeding all electric items and charging battery at
the same time. If the current has a negative sign, this means that the charging system is not able to power the electrical
loads and a significant amount of the current required must be supplied by the battery, which is therefore discharging.
Important
If polarity is reversed when clamping the ammeter onto the cable, the sign of the readings will also be reversed, giving
rise to incorrect diagnosis.
ABS diagnosis
Note
The on-screen icons used during this procedure are explained in a table at the end of this section.
If the ABS system is not working correctly, system diagnosis is possible through the DDS diagnosis instrument.
Turn on the DDS diagnosis instrument (1) referring to the paragraph ā€œ
Tester power supplyā€: use the power cord (2) part
no. 97900.0230.
Connect the power supply cable (3) part no.97900.0227 tot he power cord (2) part no. 97900.0230 and to the ABS
diagnosis connector (B) on the frame.