EPSON Stylus Pro 10000/10000CF/10600 Revision D
Stylus Pro 10600 Product Description 341
NVRAM counter value indication
Selecting this mode allows the user to indicate each life counter in decimal.
Adjustment / setup menu
This section explains the Adjustment/Setup Menu. The table below shows items that
can be adjusted/set up from this menu.
NOTE1: (*1) Only displayed when HC2/AY ink is set.
NOTE2: Underlines show default values for Adjustment/Setup items.
Each Adjustment/Setup item explained below.
Paper feed adjustment conversion system table
Paper feed adjustment converter system table is to initialize user table which can
be changed from maintenance mode 1. It normally does not involve with m2
parameter conversion of "Paper feed adjustment setup" in mechanical sequence
command. This table consist 5 type of tables.
Each table can be changed from this maintenance mode 2.
1. Conversion table for pigment printer, paper thickness setup command 0.2mm ~
0.5mm
2. Conversion table for pigment printer, paper thickness setup command 0.0mm ~
0.1mm
3. Conversion table for dye printer, paper thickness setup command 0.2mm ~ 0.5mm
4. Conversion table for dye printer, paper thickness setup command 0.0mm ~ 0.1mm
5. Conversion table for pigment/dye printer, paper thickness setup command 0.6mm
~ 1.6mm
Table 8-27. Adjustment / setup menu
Adjustment / Setup Item Panel Display Adjustment / Setup Value
Paper feed adjustment conversion
system table 1
(Pigment, PH= 0.2mm ~ 0.5mm)
XX1=<nn>:<mm>
<nn> : 00H ~ C9H
<mm> : 00H ~ C9H, FFH
Paper feed adjustment conversion
system table 2
(pigment, PH= ~ 0.1mm)
XX2=<nn>:<mm>
<nn> : 00H ~ C9H
<mm> : 00H ~ C9H, FFH
Paper feed adjustment conversion
system table 3
(dye, PH= 0.2mm ~ 0.5mm)
XX3=<nn>:<mm>
<nn> : 00H ~ C9H
<mm> : 00H ~ C9H, FFH
Paper feed adjustment conversion
system table 4
(dye, PH= ~ 0.1mm)
XX4=<nn>:<mm>
<nn> : 00H ~ C9H
<mm> : 00H ~ C9H, FFH
Paper feed adjustment conversion
system table 5 (PH= 0.6mm ~ )
XX5=<nn>:<mm>
<nn> : 00H ~ C9H
<mm> : 00H ~ C9H, FFH
System table version
XXS=<mmmm1>
<mm2>
<mmmm1> : NVRAM version
<mm2> : conversion table change
history
Failed nozzle limit (AY)
NZL_AY
0 ~ 2
~ 45
Failed nozzle limit (HC2)
NZL_HC2
0 ~ 2 ~ 45
Failed nozzle limit (HCD)
NZL_HCD
0 ~ 2
~ 45
Failed Nozzle limit (PPI)
NZL_PPI
0 ~ 2 ~ 45
Ink cartridge type
NPD
0, 1, 2, 3, 4
CSIC detection level
ED MODE
O, N, X
PG setting
N34
N, 3, 4
FLBL DET setting
FLBL DET
ON, OFF
CR speed adjustment for Bi-D print
on specific media *1
CR SPEED
285 ~ 290
~ 310
Table 8-27. Adjustment / setup menu
Adjustment / Setup Item Panel Display Adjustment / Setup Value