Attention message: NMC/Printers in common
1/12
4. Troubleshooting
41620
41620
Attent ion me ssage: NM C/Printe rs in com mon
No. 01750
Communication with the printer failed. The printer may not be active, or the LAN cable
may not be connected.
Attention message release
Retry or Continue
• If Retry is selected, the system starts connecting maintenance application and printer I/F main PCB again.
If the communication fails, the same attention is displayed.
• Select Continue to stop the process.
Condition
Check Point
Diagnosis
$ Symptoms due to connection failure of wiring/symptoms resulted from blowout of fuse
NOTE
• To access the wiring diagrams, click Wiring diagrams in Bookmarks.
Suffix number Condition
00000 The communication between the printer maintenance application and printer I/F main PCB failed.
1 Restart the computer and printer. -
2 Confirm the connection of the LAN cable. ☞4260
Countermeasure Manual No.
• Confirm the connection of the LAN cable.
☞4260
• Confirm that the settings of the IP address and the Subnet Mask are correct.
☞66005
• This error may occur if the ARCNET communication status is abnormal.
• Check the ARCNET communication status on the Version Check display.
☞35500
• Check the ARCNET communication path.
☞50520
• For details about the diagnosis of ARCNET communication error, see
☞35940.
-
Failed part Manual No.
Printer I/F main PCB
☞66005
PC -
Symptoms due to the wiring connection failure Symptoms of fuse blowout
☞4202 −−
Distributed by: minilablaser.com