8/14
4. Troubleshooting
45530
45530
Error: Processor 2
No. 05538
Backup data error. Processor
Error message release
NO
Condition
NOTE
The value informed from CPU is displayed in the last three digits of the suffix number.
If approximately 5 days have passed with the power supply being off or if the processor control PCB has been replaced with a new
one, this error message is shown.
IMPORTANT
If the error message above is shown, the backup data for the processor control PCB saved in the printer I/F main PCB is
sent to the processor control PCB within approx. 5 to 10 minutes while the error cannot be canceled.
If the backup data is sent normally, the error above can be closed.
However, the backup data saved in the printer I/F main PCB may have a problem. If the error above occurs, we
recommend you to read the backup data on the media saved at the close down check.
Diagnosis
NOTE
To access the wiring diagrams, click Wiring diagrams in Bookmarks.
Suffix number Condition
0### The backup data of the processor control PCB is abnormal.
1### The backup data of the printer I/F main PCB and processor control PCB.
If the data was deleted Manual No.
Carry out Reading data. 35400
Only for F specification, the error message
No. 05905[F], No. 05906[F], or No. 05907[F] may appear in
specific condition.
57020
Failed part Manual No.
Processor control PCB
66200
Printer I/F main PCB 66005