3/21
4. Troubleshooting
46200
46200
Error message: Printer 3
No. 06204
Setup error.
Error message release
YES
Condition
IMPORTANT
• It may occur when the processing solution is deteriorated. Confirm that the color density state of the test print have not
changed too much in comparison with the previous print.
NOTE
• See the setup print judgment flow at the daily setup. ☞56620
Diagnosis
The countermeasure action and the failed part would differ depending on the suffix number.
If the test print color density is normal
If the test print color density is abnormal
Suffix number Condition
#3001 The Dmax of the measured daily setup print was below 0.9, and the daily setup Dmax data for 15 days did not
change consecutively (the Dmax is decreasing day by day)
#3002 When calculating the daily setup correction value, the correction value density was 3 key or more. And plus
correction (print density has been decreased) has been carried out.
#3003 When calculating the daily setup correction value, the total correction value (density), which started as soon as
the initial setup or paper specification registration setup was completed, is beyond the limit value. And plus
correction (print density has been decreased) has been carried out.
Suffix number Countermeasure and failed part Manual No.
#3002
#3003
Clean the calibration plate. −
Replace the calibration plate if it is scratched on. ☞27460
Colorimeter unit
☞27460
Processor control PCB ☞66200
#3003 Problems may occur if the process of performing morning daily setup, then performing
Emulsion Number Change on the main paper when the air temperature has risen, is repeated for
several days.
In that case, perform the paper specification registration setup, then perform the paper
magazine registration setup of other magazines.
−
Even though the color density state of the test print have not changed too much in comparison
with the previous print, the correction value may have become high due to the gradual
deterioration of the processing solution.
In that case, process the control strip and check the condition of the processing solution.
−
Suffix number Countermeasure and failed part Manual No.
#3001
#3002
#3003
Process the control strip and check the condition of the processing solution. −
Clean the strainer units of the replenisher pumps and the hoses. Check the output amounts. −
Between steps
G083195