8.11.2.3.2 Routine Request
Tap this button to emulate a routine access request at the flight deck access door.
This button is disabled if the flight deck door access keypad is deactivated because an
access request has been denied or if the system controller is unpowered. When
selected, the button stays active for 2 seconds.
8.11.2.3.3 Emergency Request
Tap this button to emulate an emergency access request at the flight deck access door.
This button is disabled if the flight deck door access keypad is deactivated because an
access request has been denied or if the system controller is unpowered. When
selected, the button remains active for 2 seconds.
8.11.2.3.4 System Reset
Tap this button to reset the flight deck door RESET access system. This button is
disabled if the flight deck door access keypad is deactivated because an access
request has been denied or if the system controller is unpowered. When selected, the
button remains active for 2 seconds.
8.11.2.4 CABIN READY Section
The CABIN READY Section includes two mutually exclusive radio buttons to
activate the Cabin Ready Auto or Manual mode. Auto is usually the default mode but
when Manual mode is selected, this allows the the instructor to display a CABIN
READY indication on the ECAM/EICAS Display Unit (DU).