4-12 F650 Digital Bay Controller GE Multilin
4.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE 4 HUMAN INTERFACES
4
Table 4–2: TYPES OF FILES CREATED BY ENERVISTA 650 SETUP– ONLINE OPERATION MODE
FILE TYPE SETTINGS & CONFIGURATION FILE *.650
LOGIC CONFIGURATION FILES (*.PEP, *.AUT, *.LIB)
*.PEP *.AUT *.LIB
Relevant
sections
inside the file
Protection Settings and
Configuration Section
Compiled logic equations
section (relay configuration
and logic configuration)
Header for Logic
project
Graphical edition
container. Logic
equations (Virtual
Outputs) in FDB
format.
User programmable
logic objects
Created by EnerVista 650 Setup
Logic configuration graphic
editor (PLC Editor) and relay
configuration screen
Logic configuration
graphic editor (PLC
Editor)
Logic configuration
graphic editor (PLC
Editor)
Logic configuration
graphic editor (PLC
Editor)
Definition and
contents
Relay configuration file
containing all protection
elements, settings, input/
output and LEDs
configuration, graphic
display configuration, etc.
Equations corresponding to
the logic created and
compiled in the PLC Editor
PLC project file
containing the
necessary
information relative
to the relay model,
logic libraries
included in the
project (*.lib),
graphic file name
(*.aut), etc.
PLC Project file
containing all the
drawings used by
the logic, required
by F650 relay
based on IEC
61131-3 standard.
Functional block
diagram (FDB).
Library file to be
included as an object
in a PLC project.
Logic packages that
can be stored into
libraries and be
distributed in different
PLC projects.
Basic
information
transfer mode
to the relay
Connect with the relay (“Communications>Computer”) Connect with the relay (“Communications>Computer”)
Send settings and configuration from file: Launch 650 PLC Editor (“Setpoint>Logic Configuration”)
Send protection and
control settings to relay:
File>Send info to
relay”, select *.650 file,
choose Protection and
Control settings option in
screen and press send
Send configuration and logic
compiled equation to relay:
File>Send info to relay”,
select *.650 file, choose
“Relay and Logic
Configuration” option in
screen and press send.
When the message
“Configuration stored”
appear in the relay HMI the
configuration has been
stored.
Open the created PLC project (“File>Open Project”)
Compile the project (“Run>Compile”)
Now the logic (virtual outputs) can be sent directly to relay
(“Run>Send Equations to Relay”). Texts of virtual outputs are
not stored in the relay, only in the logic configuration files to be
edited.
Modify settings and configuration directly in the relay:
Go to “Setpoint>
>>Product Setup
>>System Setup
>>Protection Elements
>>Control Elements
>>Inputs/Outputs” in
EnerVista 650 Setup and
modify the selected
settings and press store
to send them to the relay.
Go to “Settings>Relay
Configuration>
>>Outputs
>>LEDs
>>Operations
>>Protection Elements
>>Oscillography
>>Operations
>>Control Events
>>Switchgear
>>Inputs
>>Virtual Inputs
>>Operations
>>MMI (HMI)”
in EnerVista 650 Setup,
modify the selected values
and press store to send them
to the relay.
File storage in
PC
EnerVista 650 Setup:
File>Get info from
relay”. User definable
texts retrieved are
operations, events, and
LEDs.
EnerVista 650 Setup:
The relay provides this
information in a basic format
(compiled equations). It is
necessary to have the logic
configuration files used for
creating the PLC project to
view the logic in a graphical
way (FDB) and be able to
modify it (virtual outputs).
PLC Editor:
File>Save Project “File>Save Library”
The relay will not
provide this
information unless
the *.pep file is
stored in the relay
The relay will not
provide this
information unless
the *.pep file is
stored in the relay.
The relay will not
provide this
information unless
the *.pep file is stored
in the relay.
To store the logic configuration files in the relay use the
Communication>Upload info files to relay” option
File storage inside the relay in a flash memory (RECOMMENDED): Communication>Upload info files to relay” through Ethernet
File Retrieval of relay hard disk stored files (RECOMMENDED):
Communication/Download info files from relay” through
Ethernet

Table of Contents