Special Functions | Lift off tool at NC stop: FUNCTION LIFTOFF
12
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2017
531
Resetting the lift-off function
Example
18 FUNCTION LIFTOFF RESET
Use the FUNCTION LIFTOFF RESET to reset the lift-off function.
Proceed as follows for the definition:
Show the soft-key row with special functions
Press the PROGRAM FUNCTIONS soft key
Press the FUNCTION LIFTOFF soft key
Press the LIFTOFF RESET soft key
You can also reset the lift-off with M149.
The control automatically resets the FUNCTION LIFTOFF
function at the end of a program.