Page #134 background imageLoading...
Page #134 background image
Example 2: CU Free is not used
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[RCU],Add RCU,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{S/N,MCU LDKC,MCU,RCU LDKC,RCU,SSID,Controller ID,Min.Path,
MIH Time(s),Round Trip Time(ms),FREEZE}
={99999,0x00,0x3F,0x00,0x7F,0x0004,4,08,015,001,Disable}
++{MCU Port,RCU Port}
=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},
{5G,7G},{1H,3H},{5H,7H}],Num. of Port Pairs=8
Detailed Information
DescriptionItem
Indicates a serial number of the registered RCU device.S/N
The LDKC number of the connected LDKC.MCU LDKC
The LDKC number of the paired LDKC.RCU LDKC
The path group ID of the registered RCU. When the path group ID is default setting, Default is
output.
Path Gr.ID
The controller ID of the registered RCU device.Controller ID
The CU number of the connected CU.MCU
The CU number of the paired CU.RCU
The SSID of the registered RCU.SSID
The port number of MCU.MCU Port
The port number of the registered RCU.RCU Port
The number of set minimum paths.Min.Path
The value of set RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until data
copy from MCU to RCU is completed). The unit is second.
MIH Time(s)
The round-trip response time set (delay time for round-trip remote I/O). The unit is millisecond.
This value is output when Continuous Access Synchronous or Continuous Access Synchronous
Z is used.
Round Trip Time(ms)
Indicates whether CGROUP (FREEZE/RUN) PPRC TSO command support is enabled or disabled.
This value is output only when Continuous Access Synchronous Z is used.
Enable or Disable is output.
FREEZE
The number of port pairs set.Num. of Port Pairs
[RCU] Change RCU Option
Example 1: CU Free is used
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[RCU],Change RCU Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Min.Path,
MIH Time(s),Round Trip Time(ms),FREEZE}
={99999,0x00,0x00,Default,4,08,015,001,Disable}
Example 2: CU Free is not used
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[RCU],Change RCU Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
134 Audit log examples

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers: