[Ext Stor] Assign MP Blade
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Assign MP Blade,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Group,MP Blade ID,Result}=[{E1-1,0,Normal end},{E1-2, 1,
Normal end },{E1-3, 2,Normal end }],Num. of Groups=3
Detailed Information
DescriptionItem
The external volume number for the configured external volumes.Group
The MP Blade ID assigned to the external volume.MP Blade ID
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
Result
The number of groups of configured external volumes.Num. of Groups
[Ext Stor] Delete ES VOLs
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Delete ES VOLs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{ExGroup,Mode,Result}=[{E1-1,Force,Normal end},{E1-2,Force,
Normal end},{E1-3,Normal,Normal end}],Num. of Volumes=3
Detailed Information
DescriptionItem
The number of the external volume group and the reference number assigned to the external
volume of the external volume that the mapping has been released. The number on the left of
a dash (-) is the external volume number and the number on the right of the dash (-) is the
reference number of the group.
ExGroup
The mode of execution when mapping was released.
Normal: normal execution. Force: forcible execution
Mode
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
Result
The number of volumes in the external volumes that mapping has been released.Num. of Volumes
[Ext Stor] Disconnect ES Paths
This logged information indicates that this operation was only requested but not completed.
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Disconnect ES Paths,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Port,WWN,Result}=[{1A,50560E8000C3E211,Normal end},
176 Audit log examples

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals