EasyManuals Logo

HP StorageWorks P9000 - Disk Arrays Reference Guide

HP StorageWorks P9000 - Disk Arrays
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #149 background imageLoading...
Page #149 background image
DescriptionItem
The number of parallel operation of initial copy by CU. (1 to 16).Max Initial Copy
The number of CUs set.Num. of CUs
[Cnt Ac-S] Change Pair Option
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-S],Change Pair Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{P-VOL(Port-G-ID-LUN),Fence Level,Result}
=[{1A-0x00-0x000,Never,Normal end},
{1A-0x00-0x001,Never,Normal end},
{1A-0x00-0x002,Never,Normal end},(snip)
-(snip)],Num. of Pairs=xx
Detailed Information
DescriptionItem
The port number, host group number and LUN of the primary volume where the pair option is
changed sequentially.
P-VOL(Port-G-ID-LUN)
The changed fence level (the condition that MCU rejects Write to the primary volume).
Never: No condition, Data: S-VOL data, Status: S-VOL status
Fence Level
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
Result
The number of changed pairs.Num. of Pairs
[Cnt Ac-S] Function Switch
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-S],Function Switch,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+ Switch=0001 0100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Detailed Information
DescriptionItem
Each bit position (on/off) of the function switch information assigned by 64 bits. The
beginning of the string is bit 0 and the ending of it is bit 63. "0" indicates the bit is off,
and "1" indicates the bit is on.
In the example above, bit 3 and bit 5 are on and the other bits are off.
Switch
[Cnt Ac-S] Paircreate
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-S],Paircreate,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{P-VOL(Port-G-ID-LUN),S-VOL(Port-G-ID-LUN),S/N,LDKC,ID,
Controller ID,Type,Initial Copy,Fence Level,
Continuous Access Synchronous Descriptions 149

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals