[Install] Set Subsystem Time
Example 1: The case of TOD Change
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Subsystem Time,TOD Change,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Time=YYYY/MM/DD HH:mm:SS
Example 2: The case of Synchro. Infor.
For IPv4
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Subsystem Time,Synchro. Infor.,Normal end,
xxx:xxx:xxx:xxx,,Seq.=xxxxxxxxxx
+{Use Synchro.,SNTP IP,SNTP Port,Time Zone,Check Time}
={Valid,(123.456.789.123),100,Tokyo Standard Time,24}
For IPv6
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Subsystem Time,Synchro. Infor.,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Use Synchro.,SNTP IP,SNTP Port,Time Zone,Check Time}
={Valid,(1111.1111.1111.1111.AAAA.AAAA.AAAA.AAAAA),100,
Tokyo Standard Time,24}
Basic Information
DescriptionParameter
The date and the time.TOD Change
The setting of time correction function.Synchro. Infor.
Detailed Information
DescriptionItem
Indicates the date and the time in the format of “YYYY/MM/DD HH:mm:SS”.(YYYY: year,
MM: month, DD: date, HH: hour, mm: minute, SS: second).
Time
Indicates whether the time correction function is valid or invalid.
Valid: Enable, Invalid: Disable
Use Synchro.
The IP address (IPv4 or IPv6) of SNTP server.SNTP IP
The port used by SNTP server.SNTP Port
The time zone.Time Zone
The time when the time correction function is executed. Only HH (Hour: 00 to 23) is indicated
for the execution time.
Check Time
[Install] Set UserAuth
Example
07xx, YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set UserAuth,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{LDKC:CU:LDEV,UserAuth}=[{0xXX:0xXX:0xXX,Enable}],
Num. of LDEVs=1
[Install] Cache Residency Prestaging 81

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals