Page #167 background imageLoading...
Page #167 background image
Detailed Information
DescriptionItem
The LDKC number where the journal belongs.LDKC
The journal number.JNL
The mirror ID.MirrorID
The speed of initial copy. 150: Low speed, 500: Medium speed, 1500: High speedCopy Pace
The path blockade watch period set. The units are minutes, hours or days. If it is set to 30
minutes, it will be 30 (min.).
Path Blockade
Watch(m)
Indicates whether to transfer the path blockade watch period of the master journal to the restore
journal.
Yes: Transfer, No: Do Not Transfer.
Forward Path
Blockade Watch
The transfer speed of the communication line. The unit is megabits per second (Mbps).Transfer Speed(Mbps)
Indicates the operation mode when Delta resync operation have failed.
Entire: Copy the entire data volume, None: Do not copy the data volume
Delta resync Failure
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
Result
The number of mirrors.Num. of Mirrors
[Cnt Ac-J Z] Clear-SIM
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-J Z],Clear-SIM,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
[Cnt Ac-J Z] Delete-Pair
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-J Z],Delete-Pair,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{P-VOL(LDKC:CU:LDEV),S-VOL(LDKC:CU:LDEV),MirrorID,
S/N,CTRLID,Type,Range,Delete Mode,Result}
=[{0x00:0x00:0x00,0x00:0x20:0x00,0x00,0x00,65432,5,
P-VOL,Volume,Normal,Normal end},(snip)
-{0x00:0x00:0x02,0x00:0x20:0x02,0x00,0x00,65432,5,P-VOL,Volume,
Normal,Normal end},Num.of Pairs=3
Detailed Information
DescriptionItem
The LDKC, CU, and LDEV numbers of the primary data volume.
If the LDKC:CU:LDEV is set using a spreadsheet and the Type is S-VOL, N/A will be
output for both CU and LDEV numbers.
P-VOL(LDKC:CU:LDEV)
The LDKC, CU, and LDEV numbers of the secondary data volume.
If the LDKC:CU:LDEV is set using a spreadsheet and the Type is P-VOL, N/A will be
output for both CU and LDEV numbers.
S-VOL(LDKC:CU:LDEV)
Continuous Access Journal Z Descriptions 167

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals